40
Table 5. Remote Programming Mode Commands - Continued
OP
CODE
(HEX)
MNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT
A2 SNDDLY
Determines rate of delay in
milliseconds for sending macros.
This command used when
interfacing with slow systems.
COMMAND: A2CxDx<CR>
A2 = Op Code
Cx = hex value for low nibble
Dx = hex value for high nibble
Range = 00 - FF; Where 00 is no
delay and each increment in
count equals 10 mS
<CR> = terminate command (0D hex)
ACKNOWLEDGEMENT: NONE